It allows engineers to create an affordable automated end-to-end test environment with each UE shielded individually. It enables the user to perform wireless network tests in the development, production, and/or quality assurance environment.
Honeycomb Vents and Exhaust Fans are utilized to provide ventilation in an RF Shielded Box without degrading RF Shielding Effectiveness. Shielding Enclosures is conducive to testing all wireless technologies including 5G/LTE/Base Stations, Wi-Fi, Bluetooth, ZigBee, WiMAX, etc.
The shield boxes can not only offer RF isolation and reliable signal connections necessary for testing CardBus, Mini PCI and USB device of Notebook PC in a test system. but also provides an excellent value for the test needs of the production line, R&D, service, and QC. the This makes test box
Manual Shielded Enclosures
MS262018 Manual RF Shield Box
This MS262018 compact manual RF test enclosures that provide a wide frequency Range of 0.8-3GHz and Isolation of >70dB and Frequency Range of 3-6GHz and Isolation of >60dB.This shield boxes can not only offer RF isolation and reliable signal connections necessary for testing CardBus, Mini PCI and USB device of Notebook PC in a test system. but also provides an excellent value for the test needs of the production line, R&D, service, and QC. It can be used for benchtop or mobile shield boxes at anywhere because of its small size.

(L)230x(W)310x(H)70mm
MS233107 Manual RF Shield Enclosure
MS233107 provides RF isolation and signal connections necessary for mobile testing. With the RF coupling accessories and filtered control ports, this small rf isolation cabinet makes an ideal solution for testing mobiles, Bluetooth, DAB/DMB, RFID, Zigbee and small RF devices on the test benches of manufacturing, R&D, service, and QC. This portable manual cabinet makes it simple to load and unload the device under test with its top load access door.

(L)250x(W)400x(H)280mm
MS254028 Manual RF Shield Box
Tabletop RF Test Enclosures are cells for conducting sensitive DUT measurements requiring shielding, such as mobile phones. It is the right ultimate enclosure for you to test TDMA, CDMA, AMPS, PCS, GMS, P2T, PDA, and other wireless communications devices. To allow proper cooling of the DUT, each layer includes a built-in fan option

(L)200x(W)200x(H)200mm
MS353328 Manual RF Shield Enclosure
Tabletop RF Test Enclosures are cells for conducting sensitive DUT measurements requiring shielding, such as mobile phones.It is the right ultimate enclosure for you to test TDMA, CDMA, AMPS, PCS, GMS, P2T, PDA, and other wireless communications devices.The heavy duty RF sealed cover hinges open and close with a precision air piston. Once closed, a large RF tight viewing window overlooks the entire working area within the enclosure.

(L)230x(W)300x(H)100mm
MS233010 Manual RF Shield Enclosure
Test wireless devices in a cost-effective RF enclosure. RF shielded boxes are essential for reliably testing radio interfaces. The upgraded version RF test boxes enable reliable and reproducible measurements when a shielded test environment is needed.

(L)450x(W)450x(H)350mm
MS454535 Manual RF Shielding Chamber
Honeycomb Vents and Exhaust Fans are utilized to provide ventilation in an RF Shielded Box without degrading RF Shielding Effectiveness. For handheld wireless devices such as pagers & cellular phones. This manual shield box's unique features of small size, ease of use and safety make them ideal enclosures for troubleshooting and Quality Assurance testing. Long life door gasket material along with double edge engagement not only provides solid RF shielding but smooth trouble-free operation over its lifespan.

(L)800x(W)800x(H)800mm
MS808080 LARGE Manual RF Shielding Enclosures
Manual of shield box is always used to test devices in both product research & development and production efficiency enhancement without limitations. With Frequency Range of 0.8-6GHz and Isolation of >70dB, Osprey has developed different shielding enclosures with different dimensions and shape.

(L)600x(W)600x(H)600mm
MS606060 Manual RF Shielding Enclosures
Manual of shield box is always used to test devices in both product research & development and production efficiency enhancement without limitations. With Frequency Range of 0.8-6GHz and Isolation of >70dB, Osprey has developed different shielding enclosures with different dimensions and shape.

(L)400x(W)400x(H)400mm
MS404040 Manual RF Shield Enclosure
Manual RF shield box is always used to test devices in both product research & development and production efficiency enhancement without limitations. With Frequency Range of 0.8-6GHz and Isolation of >70dB, Osprey has developed different shielding enclosures with different dimensions and shape.

(L)500x(W)445x(H)220mm
MS504422-Dual Door Manual Signal Isolating Enclosures
This rf test box shall test four DUT at the same time to enhance production efficiency and able to eliminate any leakage along the perimeter of the RF enclosure. This makes test box condusive to testing all wireless technologies including: 5G/LTE, Wi-Fi, Bluetooth,ZigBee, WiMAX, etc. Each shielded enclosure is machined from a single piece of aluminum to ensure fit and function. The clam shell design provides ample space for easy access to the DUT. The spacious interior makes it possible to test multiple DUTs inside one single rf test box.

(L)470x(W)395 x(H)590mm
MS473959 Manual RF Shield Box
Manual RF shield box is always used to test devices in both product research & development and production efficiency enhancement without limitations. With Frequency Range of 0.8-6GHz and Isolation of >70dB, Osprey has developed different shielding enclosures with different dimensions and shape.

(L)470x(W)395 x(H)590mm
MS668030 Manual RF Shield Box
Pneumatic shielding box for aging and lifetime testing.This rf test box shall test four DUT at the same time to enhance production efficiency and able to eliminate any leakage along the perimeter of the RF enclosure. This makes test box condusive to testing all wireless technologies including: 5G/LTE, Wi-Fi, Bluetooth,ZigBee, WiMAX, etc. Each shielded enclosure is machined from a single piece of aluminum to ensure fit and function. The clam shell design provides ample space for easy access to the DUT. The spacious interior makes it possible to test multiple DUTs inside one single rf test box.

(L)370x(W)390((H)225mm
MS373922 Manual RF Shielded Enclosure
With its unique 'clamshell' style construction, this manual rf test box allows easy entry to the enclosure while still maintaining the excellent RF isolation. Using our standard sized I/O plate, there is plenty of room to allow a wide variety of connectors to be utilized. These plates are easily changed and allow one to use the same enclosure for a multitude of different I/O configurations. Featuring rugged welded aluminum construction, you can be assured of its tight RF shielding effectiveness. Long life door gasket material along with double edge engagement not only provides solid RF shielding, but smooth trouble free operation over its lifespan

1000(L)x1000(W)x(H)1000 mm
MS100100 EMI Manual Signal Isolating Enclosures
Largest benchtop enclosure is ideal for tall RF devices.Its wide selection of I/O connectors allow almost any device to be interfaced inside the enclosure, and internal electromagnetic absorbing material reduces RF reflections and hot-spots

(L)500x(W)500x(H)450mm
MS505045 Manual RF Shield Enclosure
Manual RF shield box is always used to test devices in both product research & development and production efficiency enhancement without limitations. With Frequency Range of 0.8-6GHz and Isolation of >70dB, Osprey has developed different shielding enclosures with different dimensions and shape.